Generator Sets: HiPower Rental
|


HIPOWER RENTAL GENERATORS (VIEW PDF BROCHURE)
|
HRYW 25 T6 |
HRYW 40 T6 |
HRYW 50 T6 |
HRJW 35 T6 |
HRJW 60 T6 |
HRJW 75 T6 |
| HIPOWER RENTAL GENSET MODEL |
|
|
|
|
|
|
| Prime Power (P.R.P.) - kVA / kW - (0.8 PF) - 480 V |
25 / 20 |
41/33 |
50 / 40 |
33 / 26 |
61 / 49 |
73 / 59 |
| Standby Power (S.T.B.) - kVA / kW - (0.8 PF) - 480 V |
28 / 22 |
45/36 |
55 / 44 |
37 / 30 |
68 / 54 |
81 / 65 |
| Frequency (Hz |
60 |
60 |
60 |
60 |
60 |
60 |
| Genset RPM |
1,800 |
1,800 |
1,800 |
1,800 |
1,800 |
1,800 |
|
|
|
|
|
|
|
| ENGINE |
|
|
|
|
|
|
| Manufacturer |
YANMAR |
YANMAR |
YANMAR |
JOHN DEERE |
JOHN DEERE |
JOHN DEERE |
| Model |
4TNV84T |
4TNV98 |
4TNV98T |
4024TF281-36 |
4045TF280-63 |
4045HF280-74 |
| Emissions Compliance EPA 40 CFR Part 89 |
Tier 3 - 4 int. |
Tier 3 - 4 int. |
Tier 3 - 4 int. |
Tier 3 - 4 int. |
Tier 3 |
Tier 3 |
| Oil drain pump |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Governor |
Mech. |
Elect. |
Elect. |
Elect. |
Mech. |
Mech. |
| Protection for engine hot parts |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Standard water separator fuel filter |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Secondary water separator fuel filter - RACOR type |
Opt. |
Opt. |
Opt. |
Std. |
Std. |
Std. |
| Medium duty, air filter with service indicator |
Single stage |
Single stage |
Single stage |
Two stage |
Two stage |
Two stage |
|
|
|
|
|
|
|
| ALTERNATOR |
|
|
|
|
|
|
| Newage model |
PI 144 E |
PI 144 H |
PI 144 K |
PI 144 G |
UCI224D |
UCI224F |
| Permanent Magnet Generator (PMG) /Excitation boots system (EBS) |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Automatic voltage regulator (+/- 1% ) |
EBS /AS480 |
EBS /AS480 |
EBS /AS480 |
EBS /AS480 |
MX 341 |
MX 341 |
| Insulation class / Protection |
H / IP23 |
H / IP23 |
H / IP23 |
H / IP23 |
H / IP23 |
H / IP23 |
| Vacuum impregnation |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
|
|
|
|
|
|
|
| CONTROL PANEL |
|
|
|
|
|
|
| Digital control panel: Displays- hours, electrical and mechanical values, alarms and safety shut downs |
CEM7 |
CEM7 |
CEM7 |
CEM7 |
CEM7 |
CEM7 |
| kW meter |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Auto start / stop - 2 wire |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Oil pressure and water temperature indicators |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Emergency stop button |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Low fuel level shutdown |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Voltage adjust potentiometer |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| MPS - Multiple Parallel System |
n.a. |
n.a. |
n.a. |
n.a. |
n.a. |
n.a. |
|
|
|
|
|
|
|
| CONTROL PANEL BOX |
|
|
|
|
|
|
| 3 Pole Main Line Circuit Breaker |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Main bus / hardwire connection panel with safety protection |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Receptacles with individual breaker protection and GFI for 110v duplex |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Voltage selector switch, lockable, with 3 positions (3 phase 277/480 V - 120/208 V - single phase 120/240 V) |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Camlocks |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
| Battery disconnect switch |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
|
|
|
|
|
|
|
| SKID BASE |
|
|
|
|
|
|
| Heavy duty skid base with forklift pockets and drawbars |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Extended run time fuel tank |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| 110% Spill containment for engine oil, coolant and fuel spills |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Easy access for cleaning |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
|
|
|
|
|
|
|
| ENCLOSURE |
|
|
|
|
|
|
| Heavy duty, 11-gauge steel, sound attenuated enclosure, powder coat paint, stainless steel hinges & hardware |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Single point lifting eye |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Emergency stop button on the exterior of enclosure (in addition to one in control panel) |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Window for viewing control panel display |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Easy access for radiator filling |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Recessed quick release couplings for external fuel supply |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
| Ratchet type door looks for secure and tight closure (keyed alike - stainless steel) |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Noise level dB(A) @ 23 ft, full load |
57 |
63 |
62 |
63 |
70 |
72 |
| Dimensions L (in.) |
88.6 |
88.6 |
88.6 |
88.6 |
110.6 |
110.6 |
| Dimensions W (in.) |
43.3 |
43.3 |
43.3 |
43.3 |
45.3 |
45.3 |
| Dimensions H (in.) |
53.4 |
53.4 |
53.4 |
53.4 |
70.1 |
70.1 |
| Dry weight (lbs.) |
2400 |
2560 |
2600 |
2260 |
3750 |
3820 |
| Enclosure type |
CR |
CR |
CR |
CR |
D2R |
D2R |
|
|
|
|
|
|
|
| TRAILER |
|
|
|
|
|
|
| Highway legal trailer D.O.T. approved |
opt. |
opt. |
opt. |
opt. |
opt. |
opt. |
|
|
|
|
|
|
|
| FUEL SYSTEM |
|
|
|
|
|
|
| Extended run time fuel tank capacity - gallons / run time at 100% prime rating (hours) |
26.4 / 13.4 |
26.4 / 9.2 |
26.4 / 7.8 |
26.4 / 10.5 |
75.2 / 17.9 |
75.2 / 16.1 |
| External filling with lockable filler cap |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Easy access for fuel tank cleaning and draining |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Three way fuel valve with quick disconnect fittings |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
| Automatic fuel transfer pump |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
|
|
|
|
|
|
|
| EXHAUST |
|
|
|
|
|
|
| Residential Silencer (35 dB(A) reduction) with rain cap |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
RYW YANMAR, HRJW JOHN DEERE
| HRJW 90 T6 |
HRJW 115 T6 |
HRJW 145 T6 |
HRJW 175 T6 |
HRJW 235 T6 |
HRJW 250 T6 |
HRJW 310 T6 |
HRJW 340 T6 |
HRJW 400 T6 |
HRJW 460 T6 |
| 92 / 74 |
115 / 92 |
147 / 117 |
175 / 140 |
234 / 187 |
251 / 201 |
309 / 247 |
341 / 273 |
402 / 321 |
461 / 369 |
| 101 / 81 |
127 / 101 |
161 / 129 |
193 / 155 |
258 / 206 |
280 / 224 |
344 / 275 |
378 / 303 |
442 / 354 |
506 / 405 |
| 60 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
| 1,800 |
1,800 |
1,800 |
1,800 |
1,800 |
1,800 |
1,800 |
1,800 |
1,800 |
1,800 |
| |
|
|
|
|
|
|
|
|
|
| JOHN DEERE |
JOHN DEERE |
JOHN DEERE |
JOHN DEERE |
JOHN DEERE |
JOHN DEERE |
JOHN DEERE |
JOHN DEERE |
JOHN DEERE |
JOHN DEERE |
4045HF
285-94 |
4045HF
285-118 |
4045HF
285-147 |
6068HF
285-177 |
6068HF
485-235 |
6090HF
484-258 |
6090HF
484-315 |
6135HF
485-345 |
6135HF
485-401 |
6135HF
485-460 |
| Tier 3 |
Tier 3 |
Tier 3 |
Tier 3 |
Tier 3 |
Tier 3 |
Tier 3 |
Tier 3 |
Tier 3 |
Tier 3 |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Elect. |
Elect. |
Elect. |
Elect. |
Elect. |
Elect. |
Elect. |
Elect. |
Elect. |
Elect. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Two stage |
Two stage |
Two stage |
Two stage |
Two stage |
Two stage |
Two stage |
Two stage |
Two stage |
Two stage |
| |
|
|
|
|
|
|
|
|
|
| UCI224G |
UCI274D |
UCI274E |
UCI274F |
UCI274H |
UCDI274J |
HCI444D |
HCI444D |
HCI444E |
HCI444F |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| MX 341 |
MX 341 |
MX 341 |
MX 341 |
MX 341 |
MX 341 |
MX 341 |
MX 341 |
MX 341 |
MX 341 |
| H / IP23 |
H / IP23 |
H / IP23 |
H / IP23 |
H / IP23 |
H / IP23 |
H / IP23 |
H / IP23 |
H / IP23 |
H / IP23 |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| |
|
|
|
|
|
|
|
|
|
| CEM7 |
CEM7 |
CEM7 |
CEM7 |
CEM7 |
CEM7 |
CEM7 |
CEM7 |
CEM7 |
CEM7 |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
| |
|
|
|
|
|
|
|
|
|
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
n.a. |
n.a. |
n.a. |
n.a. |
n.a. |
n.a. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Opt. / 2 position |
Opt. / 2 position |
Opt. / 2 position |
| Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| |
|
|
|
|
|
|
|
|
|
| Std. |
Std. |
Std. |
Std. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| |
|
|
|
|
|
|
|
|
|
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| 72 |
72 |
74 |
74 |
75 |
75 |
79 |
79 |
79 |
79 |
| 132.3 |
132.3 |
132.3 |
132.3 |
149.6 |
161.4 |
161.4 |
177.2 |
177.2 |
177.2 |
| 49.2 |
49.2 |
49.2 |
49.2 |
55.1 |
63 |
63 |
70.9 |
70.9 |
70.9 |
| 74 |
74 |
74 |
74 |
103 |
102.4 |
102.4 |
107.9 |
107.9 |
107.9 |
| 4690 |
4690 |
4990 |
5200 |
7640 |
9370 |
9370 |
12650 |
13090 |
13090 |
| ER |
ER |
ER |
ER |
F1 |
G1 |
G1 |
H1 |
H1 |
H1 |
| |
|
|
|
|
|
|
|
|
|
| opt. |
opt. |
opt. |
opt. |
opt. |
opt. |
opt. |
opt. |
opt. |
opt. |
| |
|
|
|
|
|
|
|
|
|
| 130.7 / 21.6 |
130.7 / 17.3 |
130.7 / 14.3 |
130.7 / 12.0 |
262.7 / 19.2 |
438.2 / 28.2 |
438.2 / 23.8 |
554.4 / 28.0 |
554.4 / 23.9 |
554.4 / 20.8 |
| Std. |
Std. |
Std. |
Std. |
Internal fill |
Internal fill |
Internal fill |
Internal fill |
Internal fill |
Internal fill |
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
| Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
| Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
Opt. |
| |
|
|
|
|
|
|
|
|
|
| Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
Std. |
HRPW PERKINS, HRVW VOLVO
|
HRPW 515 T6 |
HRPW 585 T6 |
HRVW 630 T6 |
HRVW 695 T6 |
| HIPOWER RENTAL GENSET MODEL |
|
|
|
|
| Prime Power (P.R.P.) - kVA / kW - (0.8 PF) - 480 V |
512 / 410 |
582 / 469 |
632 / 505 |
695 / 556 |
| Standby Power (S.T.B.) - kVA / kW - (0.8 PF) - 480 V |
577 / 462 |
638 / 512 |
693 / 555 |
764 / 611 |
| Frequency (Hz |
60 |
60 |
60 |
60 / 1,800 |
| Genset RPM |
1,800 |
1,800 |
1,800 |
60 / 1,800 |
|
|
|
|
|
| ENGINE |
|
|
|
|
| Manufacturer |
PERKINS |
PERKINS |
VOLVO |
VOLVO |
| Model |
2506D E15TAG1 |
2506C E15TAG3 |
TAD1642GE |
TWD1643GE |
| Emissions Compliance EPA 40 CFR Part 89 |
Tier 3 |
Tier 2 |
Tier 2 |
Tier 2 |
| Oil drain pump |
Std. |
Std. |
Std. |
Std. |
| Governor |
Elect. |
Elect. |
Elect. |
Elect. |
| Protection for engine hot parts |
Std. |
Std. |
Std. |
Std. |
| Standard water separator fuel filter |
Std. |
Std. |
Std. |
Std. |
| Secondary water separator fuel filter - RACOR type |
Opt. |
Opt. |
Opt. |
Opt. |
| Medium duty, air filter with service indicator |
Single stage |
Single stage |
Single stage |
Single stage |
|
|
|
|
|
| ALTERNATOR |
|
|
|
|
| Newage model |
HCI544C |
HCI544C |
HCI544E |
HCI544F |
| Permanent Magnet Generator (PMG) /Excitation boots system (EBS) |
Std. |
Std. |
Std. |
Std. |
| Automatic voltage regulator (+/- 1% ) |
MX 341 |
MX 341 |
MX 341 |
MX 341 |
| Insulation class / Protection |
H / IP23 |
H / IP23 |
H / IP23 |
H / IP23 |
| Vacuum impregnation |
Std. |
Std. |
Std. |
Std. |
|
|
|
|
|
| CONTROL PANEL |
|
|
|
|
| Digital control panel: Displays- hours, electrical and mechanical values, alarms and safety shut downs |
CEM7 |
CEM7 |
CEM7 |
CEM7 |
| kW meter |
Std. |
Std. |
Std. |
Std. |
| Auto start / stop - 2 wire |
Std. |
Std. |
Std. |
Std. |
| Oil pressure and water temperature indicators |
Std. |
Std. |
Std. |
Std. |
| Emergency stop button |
Std. |
Std. |
Std. |
Std. |
| Low fuel level shutdown |
Std. |
Std. |
Std. |
Std. |
| Voltage adjust potentiometer |
Std. |
Std. |
Std. |
Std. |
| MPS - Multiple Parallel System |
Opt. |
Opt. |
Opt. |
Opt. |
|
|
|
|
|
| CONTROL PANEL BOX |
|
|
|
|
| 3 Pole Main Line Circuit Breaker |
Std. |
Std. |
Std. |
Std. |
| Main bus / hardwire connection panel with safety protection |
Std. |
Std. |
Std. |
Std. |
| Receptacles with individual breaker protection and GFI for 110v duplex |
n.a. |
n.a. |
n.a. |
n.a. |
| Voltage selector switch, lockable, with 3 positions (3 phase 277/480 V - 120/208 V - single phase 120/240 V) |
Opt. / 2 position |
Opt. / 2 position |
Opt. / 2 position |
t.b.a. |
| Camlocks |
Opt. |
Opt. |
Opt. |
Opt. |
| Battery disconnect switch |
Std. |
Std. |
Std. |
Std. |
|
|
|
|
|
| SKID BASE |
|
|
|
|
| Heavy duty skid base with forklift pockets and drawbars |
Opt. |
Opt. |
Opt. |
Opt. |
| Extended run time fuel tank |
Std. |
Std. |
Std. |
Std. |
| 110% Spill containment for engine oil, coolant and fuel spills |
Std. |
Std. |
Std. |
Std. |
| Easy access for cleaning |
Std. |
Std. |
Std. |
Std. |
|
|
|
|
|
| ENCLOSURE |
|
|
|
|
| Heavy duty, 11-gauge steel, sound attenuated enclosure, powder coat paint, stainless steel hinges & hardware |
Std. |
Std. |
Std. |
Std. |
| Single point lifting eye |
Std. |
Std. |
Std. |
Std. |
| Emergency stop button on the exterior of enclosure (in addition to one in control panel) |
Std. |
Std. |
Std. |
Std. |
| Window for viewing control panel display |
Std. |
Std. |
Std. |
Std. |
| Easy access for radiator filling |
Std. |
Std. |
Std. |
Std. |
| Recessed quick release couplings for external fuel supply |
Opt. |
Opt. |
Opt. |
Opt. |
| Ratchet type door looks for secure and tight closure (keyed alike - stainless steel) |
Std. |
Std. |
Std. |
Std. |
| Noise level dB(A) @ 23 ft, full load |
79 |
79 |
75 |
75 |
| Dimensions L (in.) |
177.2 |
177.2 |
196.9 |
196.9 |
| Dimensions W (in.) |
70.9 |
70.9 |
78.7 |
78.7 |
| Dimensions H (in.) |
107.9 |
107.9 |
90.9 |
90.9 |
| Dry weight (lbs.) |
13250 |
14250 |
15450 |
15740 |
| Enclosure type |
H1 |
H1 |
J |
J |
|
|
|
|
|
| TRAILER |
|
|
|
|
| Highway legal trailer D.O.T. approved |
opt. |
opt. |
opt. |
opt. |
|
|
|
|
|
| FUEL SYSTEM |
|
|
|
|
| Extended run time fuel tank capacity - gallons / run time at 100% prime rating (hours) |
554.4 / 19.2 |
554.4 / 17.3 |
250.8 /7.3 |
250.8 / 6.9 |
| External filling with lockable filler cap |
Internal fill |
Internal fill |
Internal fill |
Internal fill |
| Easy access for fuel tank cleaning and draining |
Std. |
Std. |
Std. |
Std. |
| Three way fuel valve with quick disconnect fittings |
Opt. |
Opt. |
Opt. |
Opt. |
| Automatic fuel transfer pump |
Opt. |
Opt. |
Opt. |
Opt. |
|
|
|
|
|
| EXHAUST |
|
|
|
|
| Residential Silencer (35 dB(A) reduction) with rain cap |
Std. |
Std. |
Std. |
Std. |
Dimensions and weights are approximate. HIPOWER reserves the right to change specifications without prior notice. The technical indications described correspond to the information available at the moment of printing or editing.
|
|
|
|
|
|
|
|
|
 |
TESTIMONIALS: |
We would like to thank you for the recent Trawler owners class last week. I think this was a very valuable course from a number of perspectives. Bell Power has excellent facilities and the ability to do both classroom and hands-on training was very helpful and lent a better understanding of the engine(s) and how it works. The trainer was a very patient and knowledgeable instructor who was very responsive to your class and tailored the subject matter very well. He spoke to us well, kept us all together and on the same page. His knowledge of the subject was impressive and his style was just right. Tim and Bob went out of their way to make this a great learning experience which is a very good reflection on Bell Power as a first- class organization.
John & Jeannie Coyle
|
| |
 |
|
|